# How to Fix a Furnace That Blows Cold Air

Source: https://firsthomefixes.com/guides/how-to-fix-a-furnace-that-blows-cold-air/
Summary: Learn how to fix a furnace that blows cold air: check the thermostat, filter and pilot, and know when the problem needs a technician.
Difficulty: Easy. Time: 15 to 30 minutes for the basic checks.

A furnace that blows cold air is usually not broken; it is protecting itself or waiting on something simple. A dirty filter, a thermostat setting or a tripped safety switch causes most no-heat calls. Here is how to fix a furnace that blows cold air, starting with the checks that cost nothing.

## 1. Check the thermostat first

1. Confirm the thermostat is set to heat, not cool or fan-only.
2. Set the temperature a few degrees above the room reading.
3. If the fan is set to on instead of auto, the blower runs constantly and pushes unheated air between heating cycles.
4. Replace the thermostat batteries if the display is dim or blank.

## 2. Give it a few minutes

1. When a cycle starts, the blower often pushes cool air for the first minute or two.
2. The burners need time to heat the exchanger before the air warms up.
3. Cold air that turns warm within a few minutes is normal behavior, not a fault.
4. Air that never warms up needs the next checks.

## 3. Replace the filter

1. A clogged filter overheats the heat exchanger, and the furnace shuts the burners off to protect itself.
2. The blower keeps running, which is why you feel cold air.
3. Pull the filter; if it is gray and matted, replace it.
4. Turn the furnace off and back on, or wait for the safety lockout to reset, then test again.

## 4. Check the pilot or igniter

1. On older furnaces, look through the sight glass for a steady blue pilot flame.
2. If the pilot is out, follow the lighting instructions on the furnace door.
3. On newer furnaces, the igniter glows before the burners light; no glow and no flame means a failed igniter.
4. A pilot that will not stay lit points to a faulty thermocouple, a common pro repair.

## 5. Check the gas supply

1. Confirm the gas valve on the furnace's own pipe is open, handle parallel to the pipe.
2. Check whether other gas appliances work; if none do, the problem is the supply, not the furnace.
3. After a gas shutoff, air in the line can delay ignition for a few cycles.
4. If you smell gas at any point, stop, leave and call the gas company.

## 6. Reset the furnace

1. Many furnaces lock out after repeated failed ignition attempts.
2. Turn the power switch off for 30 seconds, then back on.
3. Some models have a reset button on the blower housing; press it once.
4. Repeated lockouts mean something real is wrong, so do not keep resetting.

## 7. Know when to call a pro

- The burners light but shut off after seconds, which points to a dirty flame sensor or failing control board.
- The furnace short-cycles, starting and stopping every few minutes.
- You hear loud booming at ignition, which means delayed ignition and a safety risk.
- Any gas smell, soot, or a cracked heat exchanger suspicion means stop and call.

## Common mistakes

- Cranking the thermostat way up, which heats no faster but keeps the blower pushing air before the burners catch up.
- Resetting the furnace over and over instead of finding the cause of the lockout.
- Running all winter on a clogged filter, which overheats the exchanger and shortens its life.
- Opening the burner compartment with the power on; always switch the furnace off first.

## Related guides

- [How to Stop a Cold Draft From a Fireplace](/guides/how-to-stop-a-cold-draft-from-a-fireplace/)
- [How to Choose a Furnace Filter for Your Home](/guides/how-to-choose-a-furnace-filter/)
- [Heating, Cooling and Air Quality: Checks Before Service](/guides/heating-cooling-and-air-quality/)
- [How to Clean an Air Conditioner Filter for Better Cooling](/guides/how-to-clean-an-air-conditioner-filter/)

## FAQ

**Why does my furnace blow cold air then warm air?**
The blower starts before the heat exchanger warms up, so the first minute or two feels cool. Air that turns warm and stays warm is normal.

**Can a dirty filter really stop the heat?**
Yes. A clogged filter starves airflow, the exchanger overheats and a safety switch kills the burners while the blower keeps running. It is the most common cause and the cheapest fix.

**How much does a furnace repair usually cost?**
It varies widely by region and part. Simple fixes like a flame sensor cleaning are on the low end, while control boards and blowers cost more. Get a quote before authorizing work.

**Why does the furnace turn on and off every few minutes?**
That is short-cycling, usually from a clogged filter, a blocked exhaust vent or an oversized furnace. Change the filter and check the exterior vent pipes; call a pro if it continues.

When to call a pro: The burners will not stay lit, the furnace short-cycles, you smell gas, or the basic checks change nothing, since ignition and gas problems are pro work.
Safety: Turn the furnace power switch off before opening any panel, and shut off the gas if you smell it at any point. Never bypass a safety switch to keep the furnace running. If you smell gas, leave the house and call the gas company from outside.

General information only, not professional advice. Rules vary by state and city. First Home Fixes, https://firsthomefixes.com