How to Fix a Towel Warmer That Won't Heat Up
Part of: Basic plumbing
- Difficulty
- Easy to moderate
- Time
- 30 minutes to 2 hours
- Tools
- Radiator bleed key, cloth, bowl, screwdriver, TRV key or pliers, hose for flushing, thermometer
- Call a pro if
- The radiator stays cold after bleeding and balancing, the boiler pressure is low, or there is sludge in the system, since those need a heating engineer.
In this guide
A towel warmer that stays cold while the rest of the house is warm usually has air in it, a closed valve, or a blockage. The checks take minutes and save a callout. Here is how to fix a towel warmer that won't heat up.
1. Check what is cold
- Cold at the top: air in the radiator.
- Cold at the bottom: sludge or a blocked valve.
- Cold all over: valve closed, or the radiator is not balanced.
- Warm at the bottom only: sludge, needs flushing.
- Cold on one side: a stuck thermostatic valve pin.
2. Bleed it
1. Turn the heating off and let the radiator cool.
2. Put a cloth and a bowl under the bleed valve at the top.
3. Open the valve with a bleed key a quarter turn.
4. Hiss means air; close it when water dribbles steadily.
5. Check the boiler pressure and top up if it dropped.
Our guide on bleeding a radiator covers the general method.
3. Check both valves are open
1. The lockshield valve at one end may be closed.
2. Remove the cap and open it counterclockwise.
3. The thermostatic valve at the other end should be turned up.
4. A thermostatic valve pin can stick in summer; press it in and release it.
5. Set the valve to a high number and wait 20 minutes.
4. Balance the system
1. A towel warmer is often the last radiator on the run, so it gets least flow.
2. Open the lockshield valve a little more than the others.
3. Close the lockshields on the radiators nearest the boiler slightly.
4. Run the heating and check again.
5. Balancing takes patience; small turns only.
5. Deal with a stuck thermostatic valve
1. Remove the head from the valve.
2. Press the pin underneath with a small tool.
3. If it does not spring back, free it with pliers, gently.
4. Refit the head and test.
5. Replace the valve if the pin is seized solid.
6. Flush a sludged radiator
1. Close both valves.
2. Put a bowl under the bottom valve and open the bleed valve.
3. Disconnect the valve and drain into a bowl.
4. Flush with a hose from the top until the water runs clear.
5. Refit, refill and bleed again.
If the water is black, the system needs a chemical clean, which is a heating engineer's job.
7. Check the boiler and the pump
- Low boiler pressure stops radiators heating.
- A pump set too slow leaves the far radiators cold.
- A zone valve stuck closed keeps a whole circuit off.
- These are engineer checks; note the symptoms for the call.
8. Check the size for the room
1. A towel warmer sized for a small bathroom will not heat a large one.
2. Chrome towel bars give out less heat than painted steel.
3. A dual fuel rail with an electric element can top up the heat.
9. Keep it working
- Bleed the rail once a year, before winter.
- Leave the valves set, not fully closed, in summer.
- Do not hang heavy wet towels over the whole rail; it blocks the heat.
- Have the system serviced and inhibited.
Common mistakes
- Bleeding with the heating on and hot water spraying.
- Opening both valves fully and unbalancing the system.
- Forcing a stuck valve pin and breaking it.
- Ignoring black water, which means sludge.
- Replacing the radiator when the valve was shut.
FAQ
Why is my towel warmer cold at the top?
Trapped air. Bleed it with a key and check the boiler pressure afterwards.
Why is it cold at the bottom?
Sludge or a partly closed valve. Flush it and check both valves.
Does a towel warmer need balancing?
Yes, especially if it is the last radiator on the circuit.
Can I bleed a towel warmer without a key?
Some have a screw slot you can turn with a flat screwdriver. A bleed key is safer.
Related guides
- Oven Not Heating but Stovetop Works: What to Check: Oven not heating but stovetop works? Check the bake setting, self-clean latch and bake element before you...
- How to Fix a Towel Bar That Came Off the Wall: Learn how to fix a towel bar that came off the wall: repair the holes, choose anchors that hold, refit the...
- Tub Stopper Won't Hold Water: How to Fix It: Tub stopper won't hold water? Clean hair and soap off the seal, adjust the linkage or plunger, and replace a...
- How to Install a Towel Bar That Stays on the Wall: Learn how to install a towel bar so it stays up: choose the spot and height, fix into studs or use the right...
- How to Bleed a Radiator Safely and Get Heat Back: Learn how to bleed a radiator on a hot-water heating system: spot trapped air, release it with a key and...