Water Heater Maintenance Checklist: Once a Year
Part of: Basic plumbing
- Difficulty
- Easy to moderate
- Time
- About an hour once a year
- Tools
- A garden hose, a bucket, a flathead screwdriver, gloves
- Call a pro if
- The drain valve will not close after flushing, the relief valve keeps dripping, you smell gas, or the tank shows any rust streaks or moisture at the base.
In this guide
- Power off first
- Gas safety
An hour a year is the difference between a water heater that lasts eight years and one that lasts fifteen. This water heater maintenance checklist covers the five jobs that matter, in order, with the checks that tell you whether the tank is aging gracefully or plotting a flood.
1. Check the age and the last service date
1. Decode the manufacture date from the serial label, and note it in your home file.
2. Write down when the tank was last flushed and when the anode was last checked.
3. Past ten years, this checklist becomes an inspection for when to replace your water heater.
4. Photograph the label; you will want it again.
2. Test the temperature relief valve
This valve prevents the worst case, so prove it works.
1. Put a bucket under the discharge pipe.
2. Lift the valve's lever briefly and let it snap back; a burst of hot water should flow and stop cleanly.
3. No flow, or a valve that keeps dripping afterward, means replace the valve.
4. Never cap or plug the discharge pipe; a stuck valve is a repair, not a plug job.
3. Flush the sediment
1. Turn the heater off: breaker for electric, pilot setting for gas.
2. Attach a garden hose to the drain valve and run it to a drain or outside.
3. Open the valve with the cold supply still on and let the tank flush until the water runs clear.
4. Close the valve, remove the hose, refill fully before restoring heat, and run a hot faucet until air stops spitting.
5. Rumbling noises after years without a flush are explained in water heater popping noises.
4. Inspect the anode rod
The rod corrodes so the tank does not.
1. The anode rod screws into the top of the tank and sacrifices itself to corrosion.
2. Check it every two to three years, or yearly with soft water or an old tank.
3. A rod eaten to the wire, or coated in calcium, is done; how to replace an anode rod covers the swap.
4. A fresh rod on a healthy tank is the cheapest lifespan extension in plumbing.
5. Check the temperature setting
The dial affects safety, bills and wear.
1. About 120 degrees is the standard setting: hot enough, below fast-scald territory.
2. Higher settings accelerate sediment and corrosion and raise scald risk.
3. If you need hotter water for a dishwasher, use its built-in heater or sanitize cycle instead.
4. Note the setting in your records so drift is obvious next year.
6. Inspect everything you can see
Five minutes of looking catches the early leaks.
1. Check the cold inlet and hot outlet fittings for crust, verdigris or drips.
2. Look at the base and the floor pan for moisture or rust streaks.
3. On gas units, glance at the burner flame through the sight glass: mostly blue and steady.
4. Check the expansion tank if you have one; how to check a water heater expansion tank takes two minutes.
7. Clear the space around the heater
1. Keep stored items, especially anything flammable, away from a gas heater.
2. Make sure the area is dry; chronic dampness rusts the tank from outside.
3. Leave access room for the next service and for the eventual replacement.
4. Confirm the vent pipe on a gas unit is secure and unblocked.
Common mistakes
- Draining with the power on and burning out the electric elements.
- Skipping the flush for years, then forcing a seized drain valve.
- Ignoring a dripping relief valve or, worse, plugging it.
- Never checking the anode until the tank itself is rusting.
- Storing paint and cardboard against a gas heater.
FAQ
How often should you flush a water heater?
Once a year for most homes, twice where water is very hard. The flush removes the sediment that causes rumbling, slow heating and early tank failure.
What does the anode rod do in a water heater?
It corrodes in place of the tank. The rod is made to be consumed, and replacing it when it is spent is what keeps the tank itself from rusting through.
Is it safe to flush an old water heater that has never been flushed?
Carefully. Very old, neglected valves can drip after being disturbed. Flush gently, check the valve closes fully afterward, and have a plumber do it if the tank is already past ten years.
Why is my water heater popping after I flushed it?
Heavy scale that has hardened onto the tank bottom does not flush out. The noise may quiet as loose sediment clears, but baked-on scale stays, and it shortens the tank's remaining life.
Related guides
- How to Replace an Anode Rod in Your Water Heater: Learn how to replace an anode rod to extend the life of your water heater. Tools, safe steps, signs of a worn...
- How to Flush a Tankless Water Heater: The Annual Descale: How to flush a tankless water heater: circulate vinegar or descaler through the heat exchanger to clear scale...
- Water Heater Popping Noises: What Causes Them: Water heater popping noises usually mean sediment on the tank bottom. Learn the safe checks, how to flush the...
- How to Test a Pressure Relief Valve on a Water Heater: How to test a pressure relief valve on your water heater: the annual lever test that keeps the tank safe,...
- How to Flush a Water Heater to Remove Sediment: Learn how to flush a water heater to clear sediment: turn off the power or gas, connect a hose, drain the...