Electric Water Heater Element: How to Test and Replace It
Part of: Basic plumbing

- Difficulty
- Medium
- Time
- 1 to 2 hours
- Tools
- Multimeter, non-contact voltage tester, element wrench, screwdrivers, garden hose, bucket, towels, new element and gasket
- Call a pro if
- you are not comfortable with wiring, the tank leaks, the element will not unscrew or the breaker keeps tripping
In this guide
- Power off first
- Gas safety
An electric water heater has two heating elements, one near the top of the tank and one near the bottom. When one fails, you get lukewarm water or hot water that runs out fast. Learning to test and replace an electric water heater element can save a service call. The job takes about an hour and needs care with power and water.
This guide is part of our wider guide to water heater problems.
Signs of a bad element
- No hot water at all, or only lukewarm water.
- Hot water that runs out quickly. See Hot water runs out fast.
- The breaker trips when the heater runs.
- Strange noises or rumbling. See Water heater popping noises: what causes them.
First check Water heater not producing hot water for simple causes, such as a tripped breaker or a reset button.
Step by step: test the elements
1. Switch off the water heater's breaker in the main panel, then confirm it is dead with a voltage tester. Put tape on the breaker so no one turns it on.
2. Remove the access panels and the insulation. Each element has a cover.
3. Test for power with a non-contact voltage tester at the wires and terminals. It must show no power. Test again at the thermostat.
4. Disconnect the wires from one element and take a photo first.
5. Set the multimeter to the lowest ohms range.
6. Touch the probes to the two terminal screws on the element. A good element reads between about 10 and 30 ohms, depending on its wattage. No reading or an open circuit means it has failed.
7. Test for a ground fault. Place one meter lead on a terminal screw and the second lead on bare metal of the tank or the element plate. The meter should show no reading. If it shows a reading, the element is shorted to ground.
8. Test the other element the same way.
Step by step: replace the element
1. Keep the power off. Confirm it again.
2. Turn off the cold water supply to the heater.
3. Open a hot faucet in the house to let air in.
4. Connect a garden hose to the drain valve near the tank base and lead the other end to a floor drain or outside. Open the valve and drain the tank below the level of the element. You may need to drain it fully. See How to flush a water heater for the drain steps.
5. Remove the wires from the old element.
6. Unscrew the element with an element wrench. Turn counterclockwise. Some use a bolt flange, which is removed by unscrewing the bolts. Be ready for water.
7. Remove the old gasket and clean the surface of the opening.
8. Install the new element with a new gasket. Hand tighten, then use the wrench to snug it. Do not overtighten.
9. Reconnect the wires to the terminals as before.
10. Close the drain valve, then refill the tank by opening the cold water supply. Keep the hot faucet open until water runs steadily, so air is out of the tank.
11. Check for leaks at the element.
12. Replace the insulation and the covers, then turn on the power only when the tank is full.
Never turn on the power to an element that is not fully covered with water. A dry element burns out in seconds.
Signs that point to each cause
If you have no hot water, the upper element or the thermostat may have failed. If you have lukewarm water, the lower element may have failed. If the breaker trips, an element may be shorted. If water is too hot, the thermostat may be at fault. A leak at the element means a bad gasket. Corroded wires at the terminals can also cause trouble.
Match the new element
Check the label on the tank for the voltage and wattage. The element must match both. Check the type, which can be a screw-in or a bolt-in flange type. Take the old one to the store. Choose a durable type and replace both elements if one is old.
Prevention
Flush the tank once a year to remove sediment. Check the anode rod. See How to replace an anode rod. Set the thermostat to a safe level, about 120 degrees Fahrenheit. Look for leaks regularly.
Related guides
- Replace Water Heater Thermostat Safely (Electric)
- How to Check a Water Heater Expansion Tank
- Water Heater Relief Valve Dripping: What It Means and What to Do
- Water Heater Leaking From the Bottom: What to Check and What to Do
When to call a pro
The tank runs on 240 volts, which can kill. If you are not confident proving the breaker is off with a tester before touching a wire, hire a licensed electrician or plumber. Also call one if the breaker trips again after the new element goes in, if any wiring looks scorched or corroded, or if the tank is past about ten years old and showing rust, since the element swap may not be worth it. Sources: NFPA 70 (NEC), manufacturer service manual.
FAQ
Which element fails first?
The lower element often fails first, because of sediment.
Should I replace both?
If one is old, replacing both is wise.
Can I do this without draining the tank?
No. The element is below the water line.
How long do elements last?
Often many years, but hard water shortens their life.
More from this topic
- Replace Water Heater Thermostat Safely (Electric): Electric heater too hot, too cold or no hot water? Replace water heater thermostat parts safely with the...
- Hot Water Runs Out Fast: Hot water runs out fast? Check the thermostat, sediment, dip tube and heating element. Learn simple tests and...
- Water Heater Drain Valve Leak: How to Fix It: Water heater drain valve leak? Learn how to tighten, cap or replace the valve safely, and when to call a...
- Water Heater Not Producing Hot Water: Water heater not producing hot water? Check the breaker, pilot light, thermostat and sediment, plus real...
- Water Heater Takes Too Long to Heat Up: What to Check: When a water heater takes too long to heat up, the cause is usually sediment, a failing element or...